• CDIF/3 Systems
    • CDIF/3
    • CDIF/3 Expert
    • Compare systems
  • Special Offers
  • Contact
  • CDIF/3 shop
Hotline: +48 58 732 19 49
Log in to User Zone
Change country/language
  • Log in to User Zone
  • Change country/language
  • CDIF/3 Systems
    CDIF/3 CDIF/3 Expert Nex Compare systems
  • Special Offers
  • Contact
  • CDIF/3 shop

Change language and location.

Log in:

  • I want to register
  • I forgot my password
Data valid
Invalid User ID or password.
Photo coverage
  • Home
  • Photo coverage

Auto-Land Expo Ostróda 2018

06.10.2018
Ostróda, PL
Go to photo coverage

Photo coverage from the Inter Cars Fair 2017

22 - 24.09.2017
Warszawa, PL
Go to photo coverage

Meeting with customers of Auto Partner SA branch office in Płock, Poland

01.07.2017
Płock, PL
Go to photo coverage

Automechanika Fair - Birmingham

05 - 07.06.2017
Birmingham, UK
Go to photo coverage

May 2017 Events

18 - 25.05.2017
Żyrardów, Jedlnia–Letnisko, Białystok, PL
Go to photo coverage

Gordon Moto Show 2016

22.10.2016
Bydgoszcz, PL
Go to photo coverage

Mechanex Show, Donington Park

10 - 11.10.2016
Darby, UK
Go to photo coverage

Auto Partner Demo Car - Zabierzów

10.09.2016
Zabierzów, PL
Go to photo coverage

InterCars - Regietów, AutoPartner - Świebodzice

03.09.2016
Regietów, Świebodzice, PL
Go to photo coverage

Auto Partner Demo Car - Kielce

05 - 06.08.2016
Kielce, PL
Go to photo coverage

Auto Partner Demo Car - Zbiroża

09.07.2016
Zbiroża, PL
Go to photo coverage

Automechanika Fair - Birmingham

07 - 09.06.2016
Birmingham, UK
Go to photo coverage

Mechanex Show - Manchester

17 - 18.05.2016
Manchester, UK
Go to photo coverage

Photo coverage from Automotive Technology Fair 2016 in Poznan, Poland

31 - 03.03.2016
Poznań, PL
Go to photo coverage

Mechanex Show - Sandown Park

10 - 11.10.2015
Esher, UK
Go to photo coverage

Mechanex Show, Donington Park

06 - 07.10.2015
Darby, UK
Go to photo coverage

Photo coverage from the Inter Cars Fair 2015

18 - 20.09.2015
Warszawa - Centrum, PL
Go to photo coverage

II Congress of Automotive Experts

30.05.2015
Radom, PL
Go to photo coverage

Photo coverage from the Inter Cars Fair 2014

05 - 07.09.2014
Warszawa - Bemowo, PL
Go to photo coverage

Photo coverage from Automotive Technology Fair 2014 in Poznan, Poland

27 - 30.03.2014
Poznań, PL
Go to photo coverage

Photo coverage from the Inter Cars Fair 2013

06 - 08.09.2013
Warszawa - Bemowo, PL
Go to photo coverage

Photo coverage from the Inter Cars Fair 2011

02 - 05.09.2011
Warszawa - Bemowo, PL
Go to photo coverage

Photo coverage from the Inter Cars Fair 2010

05 - 06.09.2010
Warszawa, PL
Go to photo coverage

Photo coverage from Automotive Technology Fair 2009 in Poznan, Poland

07 - 10.05.2009
Poznań, PL
Go to photo coverage

Learn more

  • CDIF/3
  • CDIF/3 Expert
  • Nex
  • Compare systems
  • Development and Updates
  • CDIF/3 Demo Version
  • List of supported vehicles

Press centre

  • News
  • Updates
  • Events
  • Photo coverages
  • Media

CDIF/3 shop

  • Find the nearest dealer
  • Online Shop
  • Special Offers

Account

  • Log in to User Zone
  • CDIF/3 User Registration
  • Remind Me Password

Community

  • Training
  • Contact

CDIF/3 website

  • Privacy policy and cookies
Copyright © 2002-2019 Axes System sp. z o.o. All rights reserved.

Oscilloscope parameters
Shared features of each channel
Sampling 2.4MSPS/channel
Buffer up to 32K
Time base 10μs/div up to 10min/div
Measuring range 5mV/div up to 2kV/div2
Two standard BNC inputs
Coupling direct current (DC) or alternating current (AC)
Waveband 1MHz
Impedance 1MΩ/50pF
Max. voltage ±200Vpp
Three additional channels for voltage observation at controller's outputs
Three additional channels for current observation at controller's outputs
Two additional channels for signal observation at generator's outputs
One additional channel for battery voltage observation
Functionality
Advanced operation, display and triggering modes
Triggering from measured signal or from parameter/event of the serial diagnosis
Option of simultaneous observation of signals in all or only selected channels
Possibility to display signals in any physical units using free definable scaling functions
2 Range above 20V/div available for divider probes and high voltage probes.
Generator parameters
One small-signal, precise channel (for sensor emulation)
Output voltage -2,5V to +2,5V
Current-carrying capacity up to 50mA
Coupling direct current (DC) or alternating current (AC)
Sampling 1MSPS
Buffer up to 32K
Connection socket BNC3
One high-power channel (for power supply or control)
Output voltage 0V to +25V
Current-carrying capacity programmable from 0A to 5A
Sampling 1MSPS
Buffer up to 32K
Connection socket 4mm (so-called banana connector)
Functionality
Direct Digital Synthesis (DDS)
Both channel can operate in asynchronous (separate settings for each channel) or synchronous mode (common settings for both channels)
Ability to generate signals of any shape (arbitral generator)
Built-in library of reference signals, allowing for addition of one's own signals including those recorded with oscilloscope
Ability to generate signals previously recorded with oscilloscope
Automatic operation, triggered operation or operation synchronised by signal from BNC outputs of oscilloscope or parameter/event of the serial diagnosis
3 Output shared with the input of the second channel of the oscilloscope.
Controller parameters
Three independent outputs with defined control level ("+"/"-")
Current-carrying capacity up to 30A/channel1
Connection socket 4mm (so-called banana connector)
Basic control modes "ON/OFF", "single pulse", "pulse sequence", "PWM control"
Functionality
Advanced control modes to facilitate control of stepper motors, three-phase motors, petrol injectors, valves, DC motors , etc.
Pulse-duration modulation or pulse-width modulation of signals from oscilloscope input or with serial diagnosis parameters using free definable scaling functions
Synchronous or asynchronous channel operation
Overvoltage, short circuit, overtemperature and overload protection of outputs
Definable overload protection for each output separately
1 The aggregate current of all channels may not exceed 60A.
Important note: this page uses cookies.
On our website we use cookies to ensure the highest standard of services offered to you. To learn more about cookies, and why we use them on our website, click here.