It is very important to us to be in touch with you. Enter your telephone number or e-mail address in the field below, and our representative will contact you to answer any questions concerning the CDIF/3.
Enter your telephone number or e-mail address
Oscilloscope parameters
Shared features of each channel
Sampling
2.4MSPS/channel
Buffer
up to 32K
Time base
10μs/div up to 10s/div
Measuring range
5mV/div up to 2kV/div2
Two standard BNC inputs
Coupling
direct current (DC) or alternating current (AC)
Waveband
1MHz
Impedance
1MΩ/50pF
Max. voltage
±200Vpp
Three additional channels for voltage observation at controller's outputs
Three additional channels for current observation at controller's outputs
Two additional channels for signal observation at generator's outputs
One additional channel for battery voltage observation
Functionality
Advanced operation, display and triggering modes
Triggering from measured signal or from parameter/event of the serial diagnosis
Option of simultaneous observation of signals in all or only selected channels
Possibility to display signals in any physical units using free definable scaling functions
2 Range above 20V/div available for divider probes and high voltage probes.
Generator parameters
One small-signal, precise channel (for sensor emulation)
Output voltage
-2,5V to +2,5V
Current-carrying capacity
up to 50mA
Coupling
direct current (DC) or alternating current (AC)
Sampling
1MSPS
Buffer
up to 32K
Connection socket
BNC3
One high-power channel (for power supply or control)
Output voltage
0V to +25V
Current-carrying capacity
programmable from 0A to 5A
Sampling
1MSPS
Buffer
up to 32K
Connection socket
4mm (so-called banana connector)
Functionality
Direct Digital Synthesis (DDS)
Both channel can operate in asynchronous (separate settings for each channel) or synchronous mode (common settings for both channels)
Ability to generate signals of any shape (arbitral generator)
Built-in library of reference signals, allowing for addition of one's own signals including those recorded with oscilloscope
Ability to generate signals previously recorded with oscilloscope
Automatic operation, triggered operation or operation synchronised by signal from BNC outputs of oscilloscope or parameter/event of the serial diagnosis
3 Output shared with the input of the second channel of the oscilloscope.
Controller parameters
Three independent outputs with defined control level ("+"/"-")
Advanced control modes to facilitate control of stepper motors, three-phase motors, petrol injectors, valves, DC motors , etc.
Pulse-duration modulation or pulse-width modulation of signals from oscilloscope input or with serial diagnosis parameters using free definable scaling functions
Synchronous or asynchronous channel operation
Overvoltage, short circuit, overtemperature and overload protection of outputs
Definable overload protection for each output separately
1 The aggregate current of all channels may not exceed 60A.