September-October 2016-Update
  • Home
  • News
  • September-October 2016-Update
September-October 2016-Update
09-09-16
Software Updates

We've been working very hard throughout the summer holiday season to be able to present the latest software update to our users.

New additions to Nissan database for this update include models: 370Z Z34, Navara D40 and Tiida C11 with fault code readout and identification functions available. The so-far missing descriptions of diagnostic trouble codes are available in the database for Suzuki. This should further facilitate car repairs.

Thanks to the feedback and comments from our users we are able to continuously improve control module diagnosis, scan and Autodetect functions. The changes apply to flagship models, i.e. Megane III, Clio II, Espace IV ph2, Laguna III. These works are carried out on an ongoing basis and the results are introduced with each new update.

"Sensotronic Brake Control" in Mercedes E Class W211 includes adaptation for SBC system activation/deactivation (brake caliper pistons retraction). It is required for works on brake system, and is, additionally, the first such adaptation available for the make. 350CDI (207.423) engine in E Class W207 offers a number of adaptations (required for repairs), i.e. differential pressure sensor, hot film mass air flow sensor, air cleaner, O2 sensor or pressure control valve.

There is a new model on the list of supported vehicles - Grand Cherokee WK II with 3.0CRD V6 engine. The fourth generation of Grand Cherokee, manufactured since 2010, offers 18 control units for diagnosis. Other control units will be added in the upcoming updates.

As far as the support for control units in VAG group is concerned, new additions include i.e. codings to enable configuration of vehicle equipment - for example upon control unit replacement. Verification of new control units is now available as part of the enhanced diagnosis options.

Opel is the last make to face major modifications in this update. Many control modules offer improvements in maintaining control module communication. Control modules within this group are subject to continuous development in adding new verification IDs and advanced functions.

There are also some minor corrections as far as the operation of the software itself is concerned. We focused on further optimisation of the CDIF/3 database to ensure better workflow.

The latest CDIF/3 system edition is now available for download.

All updates can be downloaded after login in the User Zone.

Learn more

  • CDIF/3 +
  • CDIF/3 Expert +
  • Nex
  • Compare systems
  • Development and Updates
  • CDIF/3 Demo Version
  • List of supported vehicles

Press centre

  • News
  • Updates
  • Events
  • Photo coverages
  • Media

CDIF/3 shop

  • List dealer
  • Online Shop
  • Special Offers

Account

  • Log in to User Zone
  • CDIF/3 User Registration
  • Remind Me Password

Community

  • Training
  • Contact

CDIF/3 website

  • Privacy policy and cookies
  • Worn out equipment
Copyright © 2002-2023 AXES System sp. z o.o. All rights reserved.

Let us contact you!
It is very important to us to be in touch with you. Enter your telephone number or e-mail address in the field below, and our representative will contact you to answer any questions concerning the CDIF/3.

Enter your telephone number or e-mail address
Oscilloscope parameters
Shared features of each channel
Sampling 2.4MSPS/channel
Buffer up to 32K
Time base 10μs/div up to 10s/div
Measuring range 5mV/div up to 2kV/div2
Two standard BNC inputs
Coupling direct current (DC) or alternating current (AC)
Waveband 1MHz
Impedance 1MΩ/50pF
Max. voltage ±200Vpp
Three additional channels for voltage observation at controller's outputs
Three additional channels for current observation at controller's outputs
Two additional channels for signal observation at generator's outputs
One additional channel for battery voltage observation
Functionality
Advanced operation, display and triggering modes
Triggering from measured signal or from parameter/event of the serial diagnosis
Option of simultaneous observation of signals in all or only selected channels
Possibility to display signals in any physical units using free definable scaling functions
2 Range above 20V/div available for divider probes and high voltage probes.
Generator parameters
One small-signal, precise channel (for sensor emulation)
Output voltage -2,5V to +2,5V
Current-carrying capacity up to 50mA
Coupling direct current (DC) or alternating current (AC)
Sampling 1MSPS
Buffer up to 32K
Connection socket BNC3
One high-power channel (for power supply or control)
Output voltage 0V to +25V
Current-carrying capacity programmable from 0A to 5A
Sampling 1MSPS
Buffer up to 32K
Connection socket 4mm (so-called banana connector)
Functionality
Direct Digital Synthesis (DDS)
Both channel can operate in asynchronous (separate settings for each channel) or synchronous mode (common settings for both channels)
Ability to generate signals of any shape (arbitral generator)
Built-in library of reference signals, allowing for addition of one's own signals including those recorded with oscilloscope
Ability to generate signals previously recorded with oscilloscope
Automatic operation, triggered operation or operation synchronised by signal from BNC outputs of oscilloscope or parameter/event of the serial diagnosis
3 Output shared with the input of the second channel of the oscilloscope.
Controller parameters
Three independent outputs with defined control level ("+"/"-")
Current-carrying capacity up to 30A/channel1
Connection socket 4mm (so-called banana connector)
Basic control modes "ON/OFF", "single pulse", "pulse sequence", "PWM control"
Functionality
Advanced control modes to facilitate control of stepper motors, three-phase motors, petrol injectors, valves, DC motors , etc.
Pulse-duration modulation or pulse-width modulation of signals from oscilloscope input or with serial diagnosis parameters using free definable scaling functions
Synchronous or asynchronous channel operation
Overvoltage, short circuit, overtemperature and overload protection of outputs
Definable overload protection for each output separately
1 The aggregate current of all channels may not exceed 60A.